banner
News center
Our products are user-centric, easily approachable, and secure.

Development of a high

Sep 13, 2023

Scientific Reports volume 12, Article number: 22652 (2022) Cite this article

3090 Accesses

8 Altmetric

Metrics details

The application of 3D printing to biological research has provided the tissue engineering community with a method for organizing cells and biological materials into complex 3D structures. While many commercial bioprinting platforms exist, they are expensive, ranging from $5000 to over $1,000,000. This high cost of entry prevents many labs from incorporating 3D bioprinting into their research. Due to the open-source nature of desktop plastic 3D printers, an alternative option has been to convert low-cost plastic printers into bioprinters. Several open-source modifications have been described, but there remains a need for a user-friendly, step-by-step guide for converting a thermoplastic printer into a bioprinter using components with validated performance. Here we convert a low-cost 3D printer, the FlashForge Finder, into a bioprinter using our Replistruder 4 syringe pump and the Duet3D Duet 2 WiFi for total cost of less than $900. We demonstrate that the accuracy of the bioprinter's travel is better than 35 µm in all three axes and quantify fidelity by printing square lattice collagen scaffolds with average errors less than 2%. We also show high fidelity reproduction of clinical-imaging data by printing a scaffold of a human ear using collagen bioink. Finally, to maximize accessibility and customizability, all components we have designed for the bioprinter conversion are provided as open-source 3D models, along with instructions for further modifying the bioprinter for additional use cases, resulting in a comprehensive guide for the bioprinting field.

Additive manufacturing has disrupted multiple industries because it enables the fabrication of complex 3D parts, rapid design iteration, low-cost customization, and the use of a growing range of engineering-grade materials1. This transition has been supported by researchers developing new 3D printing methodologies and companies producing industrial-scale 3D printers for powder bed printing, vat polymerization, binder jetting, and material extrusion (e.g., thermoplastic filament extrusion). 3D bioprinting has the potential to bring similar improvements, using some of these techniques2,3,4, to the tissue engineering field by building cellularized constructs, and potentially functional tissues and organs5,6,7,8. Instead of polymers, metals, or ceramics, in 3D bioprinting it is the bioink that is printed, where the term bioink as used here includes high-density cell slurries, synthetic and natural hydrogels, cell-laden hydrogels, biomaterial inks, and combinations thereof. However, because 3D bioprinting is still primarily at the research and development stage, barriers to widespread adoption serve to limit innovation. Chief among these barriers is the high cost of commercial, research-grade 3D bioprinting platforms, which range from $5000 to over $1,000,000. At these price points, a capital equipment purchase and dedicated funds are typically required, which limits access to core facilities and well-funded research laboratories. Furthermore, many of these 3D bioprinting platforms are difficult to modify for custom applications without incurring additional cost, have limited compatibility with new biomaterials, and use proprietary printing software and a closed hardware ecosystem.

A solution for these issues emerged with the open-source 3D printing community that began in the early 2000s and accelerated with the expiration of national and international patents on fused deposition modeling (FDM) in 20099. For the first time, plastic 3D printing went from a relatively expensive technique, using proprietary equipment and materials dominated by large companies, to an open-source movement spurred by startup companies and inexpensive 3D printers that could be used by anyone. As early as 2012, researchers began to convert these low-cost thermoplastic printers, which were continuously being improved by the open-source community, into bioprinters capable of producing high-quality results for tens of thousands of dollars less than commercial alternatives. Similarly, early work on custom-built 3D bioprinters like the fab@home project at Cornell showed the potential of building open-source platforms at relatively low cost10. Over this period our research group converted a wide range of open-source thermoplastic printers (e.g., MakerBot Replicator, LulzBot Mini 2, PrintrBot Simple Metal, FlashForge Creator Pro, MakerGear M2) into high-performance 3D bioprinters11,12,13. This has enabled us to leverage the high-quality 3-axis motion system that these open-source printers already have while only needing to add the components, such as the syringe-pump extruder, specifically required for bioprinting cells and liquid bioinks. Further, our approach uses the same stepper motor from the original filament extruder of the thermoplastic printer to drive the syringe-pump extruder of the bioprinter. This means multiple high quality open-source software packages can be used to slice 3D models into G-code and to control the printing process, just as in plastic printing.

While there have been several publications describing 3D bioprinter modifications, including extruders we have designed12,14, as a whole the field lacks a comprehensive guide for building a complete, customizable open-source 3D bioprinter platform using validated and tested components15,16,17,18,19,20. Here, we describe the modification of a low-cost thermoplastic 3D printer that is widely available, into a sub $1000 bioprinter. Since 2018, we have run an internationally attended open-source 3D bioprinting workshop at Carnegie Mellon University where participants build their own bioprinter, learn how to use them for Freeform Reversible Embedding of Suspended Hydrogel (FRESH) 3D bioprinting, and then take the bioprinters back to their home institutions for future research. These efforts have served to validate our bioprinter designs and modifications and step-by-step guides for a range user backgrounds and experience levels, and have produced multiple high-impact publications21,22,23,24,25,26,27. While we use a FlashForge Finder as the printer here, the approach we describe is readily adaptable to nearly any low-cost and open-source extrusion 3D printer on the market. To do this we have created instructions requiring minimal knowledge of electronics or mechanical fabrication, and use previously published open-source printer components and syringe pump extruders capable of producing high quality printed constructs14. To ensure easy adoption and future customizability, we replace the proprietary motion control circuit board of the Finder with the Duet 2 WiFi, an open-source, highly adaptable, easy to use, and very well documented motion control board from Duet3D. We also outfit the printer with our Replistruder 4 open-source syringe pump, which builds on almost a decade of designs from our lab, and which has been used in multiple published studies12,14,21. The end result is a low-cost 3D bioprinter with performance on par or better than commercial alternatives and with a high degree of hardware and software customizability that is critical to printing new bioinks and developing advanced applications.

When converting a plastic 3D printer into a bioprinter there are a sequence of steps that generally occur in the same order (Fig. 1). First, the electronics and control system of the plastic printer either need to be adapted to bioprinting through modification, or they need to be replaced with an alternative. The proprietary FlashForge Finder motion control circuit board (Fig. 2A, green rectangle) is replaced with the open-source Duet 2 WiFi motion control circuit board (Fig. 2B, blue rectangle). This is done to improve the motion control performance, provide WiFi access, and to facilitate rapid firmware customization through the Duet web-based interface without needing to use additional software. The step-by-step instructions for this process are laid out for the FlashForge Finder and can be adapted for most desktop 3D printers (details provided in the supplemental assembly guide, Supplementary Figs. S1–S15, and provided Duet2 WiFi configuration files). Next, the thermoplastic extruder that came with the printer is replaced with the Replistruder 4, an open-source, high-performance syringe pump extruder we have previously developed14. Most parts of the Replistruder 4 are readily 3D printed out of plastic and assembled using commonly available hardware (Fig. 2C). A carriage platform was designed to fit on the existing linear motion components of the printer and provide a mounting point for the Replistruder 4. This X-axis carriage has pockets for the bearings already mounted on the X-axis linear rails as well as channels for routing and retaining the X-axis belt that drives motion along the axis. Additionally, four mounting points with recessed M3 hex nuts are incorporated to allow the Replistruder 4 to be attached to the X-axis carriage (Fig. 2D). The thermoplastic printhead that comes pre-installed on the Finder is replaced with the X-axis carriage/Replistruder 4 assembly (Fig. 2E,F , details in supplemental assembly guide, and Supplementary Figs. S16–S23). At the completion of these steps, the Replistruder 4 (Fig. 2G, blue arrow) is mounted on the X-axis of the printer in the X-axis carriage (Fig. 2G yellow arrow), and the motors are connected to the Duet 2 WiFi, which is positioned in the back cabinet of the bioprinter (Fig. 2H, green arrow). With these modifications the FlashForge Finder is transformed into an open-source bioprinter with a high-performance extruder and motion control system.

Steps in converting a plastic printer to a bioprinter. The plastic extruder printhead and the motion control board of the plastic printer are switched to a syringe pump extruder and Duet2 WiFi control board, respectively. The Duet2 WiFi is then configured to run a bioprinter. To bioprint, the desired 3D model is sliced into machine pathing (G-code generated with Cura Ultimaker software) and then Duet Web Control executes the print using the desired bioink. Figure created in part with BioRender.com.

Converting the FlashForge finder into a bioprinter. (A) The original motion control board and wiring (green rectangle). (B) The motion control board is replaced with the Duet 2 WiFi motion control board (blue rectangle). (C) The Replistruder 4 syringe pump extruder is printed and assembled. (D) The X-axis carriage for the FlashForge Finder is 3D printed and the Replistruder 4 is mounted to it. (E) Top-down view of the Finder's plastic extruder printhead that is to be removed. (F) Top-down view of the Replistruder 4 after it is mounted in the printer. (G) Additional view showing that the plastic extruder printhead has been replaced with a Replistruder 4 syringe pump extruder (blue arrow) mounted to a custom X-axis carriage (yellow arrow). (H) The Duet 2 WiFi is mounted in a 3D printed case covered in the back cabinet of the Finder (green arrow).

The Duet 2 WiFi provides several key advantages over the stock motion control circuit boards found in the FlashForge Finder and other low-cost desktop 3D printers. First, the Duet's WiFi based web interface allows for easy, in-browser access to printer movement, file storage and transfer, configuration settings, and firmware updates. This is in contrast to most 3D printers, where the process of editing configuration settings requires flashing the motion control board firmware using 3rd party software. This can be challenging and intimidating for an inexperienced user and may lead to accidental changes or firmware corruption. Second, the Duet 2 adds many advanced motion control improvements including (i) a 32-bit electronic controller, (ii) high performance Trinamic TMC2260 stepper controllers, (iii) improved motion control with up to 256 × microstepping for 5 axes, (iv) high motor current output of 2.8 A to generate higher power, (v) an onboard microSD card reader for firmware storage and file transfer, and (vi) expansion boards adding compatibility for 5 additional axes, servo controllers, extruder heaters, up to 16 extra I/O connections, and support for a Raspberry Pi single board computer. Finally, the online Duet 2 WiFi setup and support documentation is thorough, regularly updated, and backed up by an active user forum. While we provide a step-by-step guide for the hardware aspects of this conversion and basic setup of the Duet 2 WiFi, those looking to make additional modification are referred to the official Duet3D documentation. Together, these features provide high precision motion control and extensive expandability with an easy-to-use web interface that enables rapid customization and improved performance beyond standard desktop plastic printers.

After conversion, the X, Y, and Z axis travel limits were measured to determine the build volume of the 3D bioprinter. For the X-axis travel is 105 mm, for the Y-axis travel is 150 mm, and for the Z-axis travel is 50 mm, resulting in an overall build volume of 787.5 cm3 (Fig. 3A). For a stepper motor driven motion system, such as this 3D bioprinter and most commercial 3D printers, the most important control parameter affecting performance is the steps per mm calibration for each of the three axes. This number determines how many pulses, or steps, must be sent to the stepper motors that drive each axis to move them precisely one millimeter each. For the X and Y axes, which are belt driven, the formula for this is \(steps/mm=(steps/rotation\times microsteps)/(belt pitch\times pully teeth)\). For the Finder these parameters are the nominal pitch of the driving belt (2 mm), the number of teeth in the motor's pully (17 teeth), the number of steps in a full rotation for the motor (200 steps), and the number of microsteps that the Duet 2 WiFi interpolates between the full steps (set to 64 microsteps). In this case the nominal steps/mm for the X and Y-axis is 376.5. For the Z-axis, which uses a leadscrew, the formula is \(steps/mm=(steps/rotation\times microsteps)/(screw pitch\times screw starts)\). The finder uses a 4 start, 2 mm pitch lead screw so the nominal steps/mm for 16 × microstepping is 400 steps/mm.

Measurement and correction of printer travel. (A) The X-axis travel is 105 mm, the Y-axis travel is 150 mm, and the Z-axis travel is 50 mm. (B) The error of travel for the X-axis across a 10 mm window before correction (red) and after correction (blue). (C) The error of travel for the Y-axis across a 10 mm window before correction (red) and after correction (blue). (D) The error of travel for the Z-axis across a 10 mm window before correction (red) and after correction (blue).

When comparing 3D bioprinter performance there are several key specifications to consider that relate directly to print quality. Most thermoplastic 3D printers provide specifications for resolution, which is defined as the smallest step the printer can take in any direction. The reported numbers for the FlashForge Finder and several popular commercially available bioprinters can be found in Table 1. Additional specifications related to the motion system are positional error, which is defined as the absolute deviation of the current location of the printhead from the intended location, and repeatability, which is defined as the maximum absolute deviation in measured position from the average measured position when attempting to reach that position multiple times. These more sophisticated metrics are largely absent in the bioprinting space and can vary between individual printers based on mechanical components and accuracy of assembly. Additionally, the resolution provided in bioprinter specifications are generally ideals based off of the nominal dimensions of the gears, pulleys, and screws used to assemble the motion system. None of the previously mentioned manufacturers provide measurements of actual resolution, that is error across the full distance of travel, or repeatability. These measurements are commonly provided with ultra-high-end motion platforms such as those from Aerotech and Physik Instrumente28,29. To determine and then optimize the real world performance of these low cost 3D printer based systems it is necessary to measure the travel with an external tool.

To verify that the nominal steps/mm values were correct, we quantified positional error of our system along each axis near the center of travel with 2 µm precision. For the X-axis, there was a systematic under-travel using the nominal steps/mm (Fig. 3B, red curve). Using the maximum error at 10 mm of travel we determined the number of missed steps per mm and corrected the value, and with this corrected steps/mm the average travel error over the 10 mm window was 7.9 µm (Fig. 3B, blue curve). For the Y-axis there was systematic under-travel using the nominal steps/mm (Fig. 3C, red curve) and after correction this was reduced to 29.1 µm (Fig. 3C, blue curve). Finally, for the Z-axis there was systematic under-travel using the nominal steps/mm (Fig. 3D, red curve) and after correction was reduced to 32.3 µm (Fig. 3D, blue curve). The values also enable calculation of the unidirectional repeatability, which is the accuracy of returning to a specific position from only one side of the axis (e.g., from 0 to 5 mm) and the bidirectional repeatability, which is the accuracy of returning to a specific position from both sides of the axis (e.g., from 0 to 5 mm and from 10 to 5 mm). For the X-axis, the unidirectional repeatability was 3.9 µm, and the bidirectional repeatability was 16.4 µm. For the Y-axis, the unidirectional repeatability was 11.5 µm, and the bidirectional repeatability was 63.9 µm. For the Z-axis, the unidirectional repeatability was 8.7 µm, and the bidirectional repeatability was 38.7 µm. Together these measurements demonstrate that with calibration the travel of our converted bioprinter had a maximal error of 35 µm and repeatability in worst case situations of 65 µm. Whereas before calibration there was a linearly increasing error in position, after calibration this error is significantly decreased. Without this calibration, or at least measurement of the errors, it would be impossible to determine if flaws in printed constructs were due to the printer itself or other factors impacting print quality.

Fidelity and resolution of printed constructs are typically not quantified for 3D bioprinters because they cannot print bioinks in a manner approaching the mechanical limitations of the systems. However, with the recent advancements made in embedded bioprinting techniques such as FRESH13, it is now possible to perform extrusion bioprinting with resolutions approaching 20 µm. Thus, to demonstrate bioprinter printing performance we generated a square-lattice scaffold design consisting of 1000 and 500 µm filament spacing (Fig. 4A) to measure accuracy when FRESH printed from a collagen type I bioink (Fig. 4B). To measure the grid spacing we captured a 3D volumetric image using optical coherence tomography (OCT) (Fig. 4C)30, which revealed close agreement between the as-designed and measured dimensions (Fig. 4D). This was followed by a more complex design based on a 3D scan of an adult human ear (Fig. 4E). This model was printed using collagen (Fig. 4F). To analyze the accuracy we captured a 3D volumetric image of the printed ear using OCT (Fig. 4G, Supplementary Fig. S24)30. The 3D reconstruction demonstrates recapitulation of the features of the model and 3D gauging analysis revealed a deviation of − 29 ± 107 µm (mean ± STD) between the FRESH printed ear and the original 3D model (Fig. 4H)30. Together, these two examples demonstrate that the average error and standard deviation of the printed scaffolds are within the mechanical limitations of the bioprinter we built, and on par with commercial bioprinters31.

Printing dimensionally accurate grids and organic shapes. (A) Model of a gridded scaffold with 500 µm and 1000 µm grids. (B) Photograph of the gridded scaffold printed in collagen type I. (C) An OCT image of the gridded scaffold print. (D) Analysis of the accuracy of the gridded scaffold print (mean ± STD.; n = 11 measurements for 1000 µm grid, n = 26 measurements for 500 µm grid, p < 0.0001 [****] for 1000 µm compared to 500 µm by Student's two-tailed, unpaired t-test). (E) A 3D model of an ear. (F) A photograph of the ear printed in collagen type I. (G) An OCT volumetric image of the printed ear. (H) Quantitative gauging of the ear print against the original 3D model.

Here we have converted the FlashForge Finder plastic 3D printer into a 3D bioprinter and have provided detailed instructions for the process. While several bioprinter conversions have been published and have provided useful insight15,16,17,18,19,20, there has remained a need for a user-friendly, step-by-step conversion guide using components that are widely available and that have been validated to perform with a high level of performance. The FlashForge Finder is low cost (~ $300) and widely available around the world from online retailers, ensuring it will be accessible broadly to the research community. Additionally, we use a well-supported, open-source 3D printer motion control circuit board, the Duet 2 WiFi from Duet3D. All the components required for the conversion are either 3D printed in plastic, such as PLA, or widely available basic fastening, linear motion, and motor hardware. The total cost, including the Replistruder 4 components, is less than $900. Furthermore, while the step-by-step guide (see supplemental material) provides specific instructions for the FlashForge Finder, the instructions are generalizable and can be used to convert a wide array of other 3D printers into bioprinters. For example, we have designed carriages to mount the Replistruder to other printers such as the MakerGear M2 and LulzBot Mini 2 (part files downloadable at https://doi.org/10.5281/zenodo.7496012). Together, these elements make our conversion both an easy-to-use introduction for a novice and a starting point for more advanced 3D printer conversions and customizations.

Essential to the 3D bioprinting process is ensuring that the object being printed matches the dimensions and geometry of the input 3D CAD model. For the Replistruder 4 syringe pump extruder, this verification has been performed in previously published work14. For the 3D bioprinter built here, nominal values for motion control parameters produced a maximum error over a 10 mm travel range of ~ 100 µm, or ~ 1% (Fig. 3B–D). For many bioprinting applications this is adequate accuracy, however, we show that by further calibrating the printer the accuracy can be improved three-fold to ~ 33 µm (Fig. 3B–D). Considering that most bioprinter nozzle diameters range from 100 to 500 µm, this will produce high quality results for a wide range of applications12,13,30. While analysis of the motion control system is important, it does not provide a full assessment of bioprinter performance. For a complete assessment of performance, we took guidance from the testing used for high performance subtractive machining, where machined parts are measured to demonstrate fidelity. In bioprinting, a comparable assessment of fidelity can be performed by measurement of the 3D bioprinted parts (i.e., constructs). This methodology is more relevant than just XYZ travel resolution of the printer, because the fidelity of bioprinted parts also depends on material and chemical interactions that occur during fabrication. As far as we are aware, current bioprinter manufactures do not measure fidelity of printed parts (i.e., constructs) made with their bioprinters, which makes direct comparison with our open-source bioprinter difficult.

For our first print characterization, the square lattice scaffold, the 1000 and 500 µm grids matched their intended dimensions closely and the slight deviations are thought to be due to post-print handling of the 90 µm diameter, 1000 µm long collagen filaments. In line with this reasoning, the 500 µm grid, which differed only by having more frequent contact points between orthogonal filaments, had improved accuracy compared to the 1000 µm grid. The second print, the ear scaffold, showed that the bioprinter can produce more complex 3D shapes and the quantitative gauging analysis confirmed that the fidelity achieved using collagen bioink was similar to our published results using other FRESH 3D bioprinters13,14,32. Other important characteristics of FRESH printed collagen constructs, such as stability over time and biocompatibility, have been extensively described in our prior work13,30,32. These examples demonstrate that the converted 3D bioprinter is capable of both accurate motion and high-fidelity printing of the intended geometry.

An important aspect of open-source hardware, aside from its lower cost, is the ability to modify and expand its capabilities for specific applications. For the previously published Replistruder 4 syringe pump extruder we provided complete print and design files that are easily modified in standard CAD software. Here we build upon this by providing complete print and design files for the X-axis carriage and various sample holders, including for 35 mm Petri dishes and multi-well plates. These files enable modification of the printer for various syringe types and sizes, as well as for various print containers. The Duet 2 WiFi allows for expanded capabilities as well, including print bed and syringe heaters and chillers, and sensors that can be controlled using its advanced implementation of G-code. Additional tools are also supported such as multiple syringe pump extruders, lasers, subtractive tools (e.g., mills), UV light switching, automated tool switching, and G-code macros. Together this broad potential for extensibility and modification makes our 3D bioprinter a powerful platform for the development of advanced 3D bioprinting applications.

Finally, the 3D bioprinter we have developed here is the result of multiple years of development, during which we worked with engineers, scientists, and physicians, and trained them to build and use these systems. It is based on the "3D Bioprinting Open-Source Workshop" that we have organized at Carnegie Mellon University since 2018, and where we have taught trainees from research labs across the world, including Australia, Canada, Israel, Japan, Korea, and the United States. The conversion of the FlashForge Finder into a 3D bioprinter described here was used for the 2021 and 2022 workshops and served as the basis for the included step-by-step conversion guide (see supporting material). Through this publication we hope to expand the number researchers that can learn and benefit from this effort. Further, we hope that this 3D bioprinter can serve as an example of the impact that open-science can have on accelerating research advances and the importance of putting low-cost and high-performance scientific tools in the hands and labs of as many researchers as possible.

To measure travel of the printer with high precision we utilized a Mitutoyo Absolute Digimatic Indicator (Mitutoyo, Japan, 542-500B) with ± 2 µm accuracy mounted to a Noga magnetic base for alignment with the axes of the printer. To measure a given axis the gauge was aligned parallel to the axis and then run to full travel then backed off to 100 µm less than its full travel using the printer controls on the Duet Web Control (to ensure any backlash on the initial travel was taken up). The axis was then moved away from the gauge in 1 mm nominal increments using the Duet Web Control. The actual position, taken from the gauge, was recorded. This process was repeated until a 10 mm nominal travel was complete, then the process was reversed until the nominal position was 0 again. The zero position was reset, and the process was repeated two more times. From these measurements the error was defined as the absolute difference between the nominal position and the measured position. The unidirectional repeatability was the error for the second and third trials when returning to each of the positions in each direction when compared to the first trial. The bidirectional repeatability was the absolute value of the difference between the actual measurements of position at the paired nominal locations (moving away and then returning to zero).

To calibrate the axes the nominal steps/mm for each axis is first input into the Duet WiFi 2 configuration file. The maximal error at 10 mm travel from the three trials was determined, and then the steps/mm for each axis was scaled proportionately to the error. That is if the nominal steps/mm was 376.5 and there was a total travel of 9.887 mm the correction would be (10 mm)/(9.887 mm) × (376.5 steps/mm) = 380.8 steps/mm. This process was then repeated for the other two axes. After calibration, the measurement process can be repeated to verify the accuracy.

All 3D CAD models for printed plastic components of the FlashForge Finder conversion and the Replistruder 4 were generated using Autodesk Inventor 2020 (Autodesk). The CAD files and STL files for the Replistruder 4 can be downloaded from Zenodo at https://doi.org/10.5281/zenodo.4119127. CAD and STL files can be downloaded from Zenodo at https://doi.org/10.5281/zenodo.7496012 for the FlashForge Finder 3D bioprinter conversion, as well as files to convert the MakerGear M2 and Lulzbot Mini 2. The grid model printed with 500 and 1000 µm grid spacing was generated using Autodesk Inventor 2020. The ear model was purchased from http://www.cgtrader.com/ and was generated by seller Sakura-pms.

The G-code for printed plastic components of the Flashforge Finder conversion and the Replistruder 4 were generated using PrusaSlicer (Prusa). All models were printed from PLA plastic at 60% infill without support material. The G-code for the ear model was generated using Cura 4.3.0 (Ultimaker). The G-code for the grid model was generated using Simplify 3D (Simplify3D).

FRESH v2.0 gelatin microparticle support bath was generated via a complex coacervation method to produce gelatin microparticles, based on published methods13. Briefly, 2.0% (w/v) gelatin Type B (Fisher Chemical), 0.25% (w/v) Pluronic® F-127 (Sigma-Aldrich) and 0.1% (w/v) gum Arabic (Sigma-Aldrich) were dissolved in a 50% (v/v) ethanol solution at 45 °C in a 1 L beaker and adjusted to 7.5 pH by addition of 1 M hydrochloric acid. An overhead stirrer (IKA, Model RW20) was then used to maintain mixing while the beaker was sealed with parafilm to minimize evaporation, and the mixture cooled to room temperature with stirring overnight. The resulting solution was transferred into 250 mL containers and centrifuged at 300g for 2 min to compact the gelatin microparticles. The supernatant was discarded and the gelatin microparticles were resuspended in a solution of 50 mM 4-(2-hydroxyethyl)-1-piperazineethanesulfonic acid (HEPES) (Corning) at pH 7.4. To remove the ethanol and Pluronic® F-127 the gelatin microparticle support bath was then washed three times with the same HEPES solution and stored until use at 4 °C. Prior to printing, the uncompacted support was centrifuged at 1000g for 3 min then washed with 50 mM HEPES. After the last wash, the gelatin microparticle support bath was suspended in 50 mM HEPES, degassed in a vacuum chamber for 15 min, and centrifuged at 1900–2100g, depending on level of compaction desired, for 5 min. Finally, the supernatant was removed and the gelatin microparticle support bath was transferred into a print container.

All collagen type I bioink (LifeInk 200, Advanced Biomatrix). was prepared as previously described13. Briefly, the stock 35 mg/mL LifeInk was mixed with syringes in a 2:1 ratio with 0.24 M acetic acid to produce a 23.33 mg/mL acidified collagen bioink. The bioink was then centrifuged at 3000g for 5 min to remove bubbles. For printing, the collagen bioink was transferred to a 2.5 mL gastight syringe (Hamilton Company).

Photographs of printed constructs were acquired using a Laowa 24 mm probe lens (Venus Optics) mounted to a Sony ILCE7M mirrorless digital camera. OCT 3D image stacks were acquired using a Thorlabs Vega 1300 nm OCT system with the OCT-LK4 objective (Thorlabs)30. OCT images were prepared for visualization using Fiji (ImageJ, NIH) with noise reduction, median filtering, and stack histogram equalization. The image stacks were then exported as TIF files and opened using 3D Slicer33. The volume rendering features were then used to produce 3D views of the volumetric OCT image.

Gauging was performed as we have previously described30. Briefly, a 3D volumetric image of the ear construct was captured using OCT. The image was then cleaned and segmented to produce a 3D reconstruction using 3D Slicer33. The 3D reconstruction and the original 3D model were then imported into CloudCompare (www.cloudcompare.com)34. In CloudCompare the two 3D objects were aligned and registered and then the reconstruction was gauged to the original 3D model to determine errors. Errors were calculated as mean ± STD.

Statistical and graphical analyses were performed using Prism 9 (GraphPad) and Excel (Microsoft). Statistical tests were chosen based on the experimental sample size, distribution, and data requirements. Analysis of the 1000 and 500 µm grid print was completed using Fiji (Image J NIH) and MATLAB (Mathworks). For the comparison of the two grid sizes a Student's two-tailed unpaired t test was used.

The CAD files and STL files for the Replistruder 4 can be downloaded from Zenodo at https://doi.org/10.5281/zenodo.4119127. CAD and STL files can be downloaded from Zenodo at https://doi.org/10.5281/zenodo.7496012 for the FlashForge Finder conversion to the 3D bioprinter. Any raw data not presented in the main and supplemental text is available from the corresponding author on reasonable request.

Attaran, M. The rise of 3-D printing: The advantages of additive manufacturing over traditional manufacturing. Bus. Horiz. 60, 677–688 (2017).

Article Google Scholar

Li, X. et al. Inkjet bioprinting of biomaterials. Chem. Rev. 120, 10793–10833 (2020).

Article Google Scholar

Ng, W. L. et al. Vat polymerization-based bioprinting—Process, materials, applications and regulatory challenges. Biofabrication 12, 022001 (2020).

Article ADS Google Scholar

Jiang, T., Munguia-Lopez, J. G., Flores-Torres, S., Kort-Mascort, J. & Kinsella, J. M. Extrusion bioprinting of soft materials: An emerging technique for biological model fabrication. Appl. Phys. Rev. 6, 011310 (2019).

Article ADS Google Scholar

Shiwarski, D. J., Hudson, A. R., Tashman, J. W. & Feinberg, A. W. Emergence of FRESH 3D printing as a platform for advanced tissue biofabrication. APL Bioeng. 5, 010904 (2021).

Article Google Scholar

Cui, H., Nowicki, M., Fisher, J. P. & Zhang, L. G. 3D Bioprinting for organ regeneration. Adv. Healthc. Mater. 6, 1601118 (2017).

Article Google Scholar

Derakhshanfar, S. et al. 3D bioprinting for biomedical devices and tissue engineering: A review of recent trends and advances. Bioactive Mater. 3, 144–156 (2018).

Article Google Scholar

Heinrich, M. A. et al. 3D Bioprinting: from Benches to Translational Applications. Small 2019, 1805510 (2019).

Article Google Scholar

Gonzalez, C. Infographic: The history of 3D printing. Mechanical Engineering: The Magazine of ASME (2020). https://www.asme.org/topics-resources/content/infographic-the-history-of-3d-printing.

Malone, E. & Lipson, H. Fab@Home: The personal desktop fabricator kit. Rapid Prototyp. J. 13, 245–255 (2007).

Article Google Scholar

Hinton, T. J. et al. Three-dimensional printing of complex biological structures by freeform reversible embedding of suspended hydrogels. Sci. Adv. 1, e1500758–e1500758 (2015).

Article ADS Google Scholar

Mirdamadi, E., Tashman, J. W., Shiwarski, D. J., Palchesko, R. N. & Feinberg, A. W. FRESH 3D bioprinting a full-size model of the human heart. ACS Biomater. Sci. Eng. 6, 6453–6459 (2020).

Article Google Scholar

Lee, A. et al. 3D bioprinting of collagen to rebuild components of the human heart. Science 365, 482–487 (2019).

Article ADS Google Scholar

Tashman, J. W., Shiwarski, D. J. & Feinberg, A. W. A high performance open-source syringe extruder optimized for extrusion and retraction during FRESH 3D bioprinting. HardwareX. 9, e00170 (2021).

Article Google Scholar

Ioannidis, K. et al. A custom ultra-low-cost 3D bioprinter supports cell growth and differentiation. Front. Bioeng. Biotechnol. 8, 580889 (2020).

Article Google Scholar

Kahl, M., Gertig, M., Hoyer, P., Friedrich, O. & Gilbert, D. F. Ultra-low-cost 3D bioprinting: Modification and application of an off-the-shelf desktop 3D-printer for biofabrication. Front. Bioeng. Biotechnol. https://doi.org/10.3389/fbioe.2019.00184 (2019).

Article Google Scholar

Krige, A., Haluška, J., Rova, U. & Christakopoulos, P. Design and implementation of a low cost bio-printer modification, allowing for switching between plastic and gel extrusion. HardwareX. 9, e00186 (2021).

Article Google Scholar

Yenilmez, B., Temirel, M., Knowlton, S., Lepowsky, E. & Tasoglu, S. Development and characterization of a low-cost 3D bioprinter. Bioprinting. 13, e00044 (2019).

Article Google Scholar

Bessler, N. et al. Nydus one syringe extruder (NOSE): A Prusa i3 3D printer conversion for bioprinting applications utilizing the FRESH-method. HardwareX. 6, e00069 (2019).

Article Google Scholar

Lei, I. M., Sheng, Y., Lei, C. L., Leow, C. & Huang, Y. Y. S. A hackable, multi-functional, and modular extrusion 3D printer for soft materials. Sci. Rep. 12, 12294 (2022).

Article ADS Google Scholar

Hull, S. M. et al. 3D Bioprinting using UNIversal Orthogonal Network (UNION) bioinks. Adv. Func. Mater. 31, 2007983 (2021).

Article Google Scholar

Ding, A. et al. Jammed micro-flake hydrogel for four-dimensional living cell bioprinting. Adv. Mater. 34, 2109394 (2022).

Article Google Scholar

Jeon, O. et al. Stem cell-laden hydrogel bioink for generation of high resolution and fidelity engineered tissues with complex geometries. Bioactive Mater. 15, 185–193 (2022).

Article Google Scholar

Seymour, A. J., Shin, S. & Heilshorn, S. C. 3D printing of microgel scaffolds with tunable void fraction to promote cell infiltration. Adv. Healthc. Mater. 10, 2100644 (2021).

Article Google Scholar

Yang, J., Tao, J. L. & Franck, C. Smart digital image correlation patterns via 3D printing. Exp. Mech. 61, 1181–1191 (2021).

Article Google Scholar

Romanazzo, S. et al. Synthetic bone-like structures through omnidirectional ceramic bioprinting in cell suspensions. Adv. Func. Mater. 31, 2008216 (2021).

Article Google Scholar

Molley, T. G. et al. Heterotypic tumor models through freeform printing into photostabilized granular microgels. Biomater. Sci. 9, 4496–4509 (2021).

Article Google Scholar

Homan, K. A. et al. Bioprinting of 3D convoluted renal proximal tubules on perfusable chips. Sci. Rep. 6, 34845 (2016).

Article ADS Google Scholar

Kolesky, D. B., Homan, K. A., Skylar-Scott, M. A. & Lewis, J. A. Three-dimensional bioprinting of thick vascularized tissues. Proc. Natl. Acad. Sci. U. S. A. 113, 3179–3184 (2016).

Article ADS Google Scholar

Tashman, J. W. et al. In situ volumetric imaging and analysis of FRESH 3D bioprinted constructs using optical coherence tomography. Biofabrication 15, 014102 (2023).

Article ADS Google Scholar

Tong, A. et al. Review of low-cost 3D bioprinters: State of the market and observed future trends. SLAS Technol. 26, 333–366 (2021).

Article Google Scholar

Bliley, J. et al. FRESH 3D bioprinting a contractile heart tube using human stem cell-derived cardiomyocytes. Biofabrication 14, 024106 (2022).

Article ADS Google Scholar

Fedorov, A. et al. 3D slicer as an image computing platform for the quantitative imaging network. Magn. Reson. Imaging. 30, 1323–1341 (2012).

Article Google Scholar

Girardeau-Montaut, D. Detection de changement sur des donnees geometriques tridimensionnelles. Telecom. Paris (2006).

Download references

We would like to acknowledge Brian Coffin and Andrew Hudson for reviewing the supplemental materials. We would also like to acknowledge the attendees of the Regenerative Biomaterials and Therapeutics Group's 2021 and 2022 3D bioprinting open-source workshop for real world testing of the conversion process. Additionally, we would like to acknowledge Thingiverse (www.thingiverse.com) user ChrisGilleti, who designed the original model for the Duet2 WiFi Case utilized in this conversion (thing 3721923).

This work was supported by the Food & Drug Administration (R01FD006582) and the National Heart, Lung, And Blood Institute of the National Institutes of Health (1F30HL154728, K99HL155777).

These authors contributed equally: Joshua W. Tashman and Daniel J. Shiwarski.

Department of Biomedical Engineering, Carnegie Mellon University, Pittsburgh, PA, 15213, USA

Joshua W. Tashman, Daniel J. Shiwarski & Adam W. Feinberg

Department of Materials Science and Engineering, Carnegie Mellon University, Pittsburgh, PA, 15213, USA

Adam W. Feinberg

You can also search for this author in PubMed Google Scholar

You can also search for this author in PubMed Google Scholar

You can also search for this author in PubMed Google Scholar

All authors conceived the experiments and contributed to the scientific planning and discussions. J.W.T. and D.J.S. prepared final figures and text. J.W.T. wrote the conversion guide. J.W.T. performed bioprinting and OCT imaging. J.W.T. and D.J.S. performed image analysis in Fiji and MATLAB. J.W.T., D.J.S., and A.W.F. wrote the paper and interpreted the data.

Correspondence to Adam W. Feinberg.

A.W.F. has an equity stake in FluidForm Inc., which is a startup company commercializing FRESH 3D printing. FRESH 3D printing is the subject of patent protection including U.S. Patent 10,150,258 and provisional patent No. 63/082621. No other authors have conflicts of interests.

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/.

Reprints and Permissions

Tashman, J.W., Shiwarski, D.J. & Feinberg, A.W. Development of a high-performance open-source 3D bioprinter. Sci Rep 12, 22652 (2022). https://doi.org/10.1038/s41598-022-26809-4

Download citation

Received: 11 September 2022

Accepted: 20 December 2022

Published: 31 December 2022

DOI: https://doi.org/10.1038/s41598-022-26809-4

Anyone you share the following link with will be able to read this content:

Sorry, a shareable link is not currently available for this article.

Provided by the Springer Nature SharedIt content-sharing initiative

By submitting a comment you agree to abide by our Terms and Community Guidelines. If you find something abusive or that does not comply with our terms or guidelines please flag it as inappropriate.